OZEKI NG SMS Gateway - Product Guide

Cluster Contents | SearchLive cluster setup 2

Home > Product Manual > User Guide > Administrator's guide > Cluster > Live cluster setup 1

 


Contact Us!
If you wish to get further information, do not hesitate to contact us!

E-mail: info@ozekisms.com

If you have a technical question, please submit a support request on-line.

Recommended reading:
If you wish to protect your service against hardware failure and reach higher availability of your Ozeki NG SMS Gateway software, we recommend you to try our Ozeki Cluster software product. Ozeki Cluster automatically moves any service to another computer in case of a hardware failure. You can download it from: Ozeki Cluster Site

Live cluster with two live Ozeki NG SMS Gateway Nodes "Setup 1"

In a live cluster setup both Ozeki NG SMS Gateway nodes are operational. One node serves one set of clients, the other node serves another set of clients. Both nodes have a set of active and a set of passive configurations. The passive configurations are in "Not connected" state. Passive configurations are defined for both: users and clients and service provider connections.

In this setup both system must have live accounts registered at the SMS service providers. These accounts are called "Account A1, Account A2, ..." on Figure 1.

During normal operation both Ozeki NG SMS Gateway nodes are connected to the SMS service providers.

Normal operation

During normal operation, the load of the two nodes are balanced. Each node serve a configured set of clients.

the working of the two ozeki ng sms gateway nodes during normal operation

System down operation

When one of the nodes of the cluster goes down because of hardware failure, the configurations on the other node can be activated. This way the other node can take over all the operations: all service provider connections and all client connections.

the working of the two ozeki ng sms gateway nodes during a system error

Failover switching

In this setup failover switching can be performed manually or automatically. If manual switching takes place, the system administrator must login to the live system, and activate the passive configurations by hand.

Automatic switching can be performed by Ozeki's cluster extension. In this case the Ozeki Cluster checks both nodes availability periodically (once every minute). If it detects, that one of the nodes is down, it activates the passive configuartions using HTTP requests.

We recommend manual switching, because short network outages or unintended service transfers can be avoided this way.

More information